Items |
T500 CHO-THERM® - High Power Thermally Conductive Electrical Insulator Pads |
1678 CHO-THERM® - High Power Thermally Conductive Electrical Insulator Pads |
1671 CHO-THERM® - High Power Thermally Conductive Electrical Insulator Pads |
|||
Color | N/A Green | N/A Pink | N/A White | |||
Reinforcement Carrier | N/A Fiberglass | |||||
Test Method Thicknesses | N/A ASTM D374 | |||||
Thickness | N/A 0.25 mm0.010 in | N/A 0.25 mm0.010 in | N/A 0.38 mm0.015 in | |||
Thickness Tolerance | N/A ± 0.050 mm± 0.002 in | |||||
Test Method Specific Gravity | N/A ASTM D792 | |||||
Specific Gravity | N/A 1.60 | N/A 1.55 | N/A 1.55 | |||
Test Method Hardness | N/A ASTM D2240 | |||||
Hardness, Shore A | N/A 80 | |||||
Operating Temperature Range | N/A –40 to 200 ºC–40 to 392 ºF | |||||
Test Method Thermal Impedance | N/A ASTM D5470 | |||||
Thermal Impedance | N/A 1.2 ºC-cm²/W0.19 ºC-in²/W | N/A 1.26 ºC-cm²/W0.20 ºC-in²/W | N/A 1.48 ºC-cm²/W0.23 ºC-in²/W | |||
Test Method Apparen Thermal Conductivity | N/A ASTM D5470 | |||||
Apparen Thermal Conductivity | N/A 2.1 W/m·K | N/A 2.0 W/m·K | N/A 2.6 W/m·K | |||
Test Method Heat Capacity | N/A ASTM E1269 | |||||
Heat Capacity | N/A 1.0 J/g-ºC | |||||
Test Method Coefficient of Thermal Expansion | N/A ASTM E831 | |||||
Coefficient of Thermal Expansion | N/A 250 ppm/K | |||||
Test Method Volume Resistivity Dry | N/A ASTM D149 | |||||
Volume Resistivity Dry | N/A 1016 O/cm | |||||
Test Method Voltage Breakdown Dry | N/A ASTM D149 | |||||
Voltage Breakdown Dry | N/A 4000 Vac | N/A 2500 Vac | N/A 4000 Vac | |||
Test Method Tensile Strength | N/A Chomerics | |||||
Tensile Strength | N/A 20.7 MPa3000 psi | |||||
Test Method Tear Strength | N/A Chomerics | |||||
Tear Strength | N/A 70 kN/m400 lb/in | N/A 35 kN/m200 lb/in | N/A 70 kN/m400 lb/in | |||
Test Method Elongation | N/A Chomerics | |||||
Elongation | N/A 20 % | N/A 20 % | N/A 15 % | |||
Test Method Dielectric Constant | N/A ASTM D150 | |||||
Dielectric Constant at 1000 kHz | N/A 3.5 | N/A 3.6 | N/A 3.6 | |||
Test Method Dissipation Factor | N/A Chomerics Test | |||||
Dissipation Factor at 1000 kHz | N/A 0.003 | N/A 0.007 | N/A 0.007 | |||
Test Method Flammability Rating | N/A UL 94 | |||||
Flammability Rating | N/A V-0 | N/A V-0 | N/A HB | |||
Test Method RoHS Compliant | N/A Chomeric Certification | |||||
RoHS Compliant | N/A Yes | |||||
Test Method Outgassing | N/A ASTM E595 | |||||
Outgassing TML | N/A 0.40 % | N/A 0.55 % | N/A 0.76 % | |||
Outgassing CVCM | N/A 0.10 % | N/A 0.12 % | N/A 0.07 % | |||
Test Method Shelf Life | N/A Chomerics | |||||
Shelf Life, Months from Dry Pad | N/A 24 | |||||
Shelf Life, Months from Dry Pad with PSA | N/A 18 | |||||
|