Item # 567 Primerless Silicone Encapsulant, Silicone Potting/Encapsulants
larger image
2-part, 1:1 mix, black encapsulant with good flame resistance
Specifications
·
Features
·
Potential Uses
·
Application Methods
·
Cure
Specifications
Type
Primerless Silicone Encapsulants
Mix Ratio
1:1
Color
Black
Viscosity
1540
mPa/s
Durometer
59 (Shore 00)
Specific Gravity
1.23
Working Time at Room Temperature
> 3 days
Flammability Classification
94 V-0
UL Temperature Index, Electrical/Mechanical
105/105
ºC
Unprimed Adhesion Lap Shear
140
psi
1.0
N/cm²
10
kgf/cm²
Thermal Conductivity
0.30
W/m·K
7.2 x 10
-4
cal/cm·s-ºC
Linear Coefficient of Thermal Expansion
300
ppm
Shelf Life from Date of Manufacture
24 months
Military Specification
MIL-PRF-23586F (Grade B2)
Type, Class, Group
Type I, Class IV QPL
Dielectric Strength
525
V/mil
21
kV/mm
Dielectric Constant at 100 Hz
2.85
Dielectric Constant at 100 kHz
2.79
Dissipation Factor at 100 Hz
0.008
Dissipation Factor at 100 kHz
0.002
Volume Resistivity
2.1 x 10
15
O/cm
Features
1:1 mix ratio; flowable; self-priming; heat cure; UL recognized; Mil Spec approved
Potential Uses
Low cost primerless adhesion encapsula tion applications
Application Methods
Supplied as two-part liquid component kits comprised of Part A/Part B to be mixed in a 1:1 ratio by weight or volume; automated or manual mixing and dispensing can be used
Cure
120 minutes at 100 ºC (212 °F)
60 minutes at 125 °C (257 °F)
15 minutes at 150 °C (302 °F)
Note: These data were collected on 50–100 gram samples of a lot believed to be typical and should be used as initial estimates of cure times. Times will vary slightly from batch to batch and can be longer or shorter due to thermal mass of your parts and your heating ramp rate. Pretesting is recommended to confirm adequate cure for your application.
For primerless adhesion products, cure time is based on time to reach durometer. Full adhesion may take more time at the cure temperature.