Test Method Color |
N/A Visual |
Color |
N/A Purple/gray foil |
Carrier |
N/A 1 mil Metal Foil |
Test Method Thicknesses |
N/A ASTM D374 |
Standard Thickness |
N/A 0.088 mm0.0035 in |
Test Method Specific Gravity |
N/A ASTM D792 |
Specific Gravity |
N/A 2.6 |
Test Method Phase Transition Temperature |
N/A ASTM 3418 |
Phase Transition Temperature |
N/A 55 ºC |
Weight Loss, 125 ºC for 48 h |
N/A < 0.5 % |
Test Method Thermal Impendance |
N/A ASTM D5470 |
Thermal Impendance at 70 ºC, at 69 kPa (10 psi) |
N/A 0.97 ºC-cm²/W0.15 ºC-in²/W |
Thermal Impendance at 70 ºC, at 172 kPa (25 psi) |
N/A 0.58 ºC-cm²/W0.09 ºC-in²/W |
Thermal Impendance at 70 ºC, at 345 kPa (50 psi) |
N/A 0.39 ºC-cm²/W0.06 ºC-in²/W |
Operating Temperature Range |
N/A –55 to 125 ºC–67 to 257 ºF |
Test Method Volume Resistivity |
N/A ASTM D257 |
Volume Resistivity |
N/A 1014 O/cm Metal Foil (electrically conductive) |
Test Method Voltage Breakdown |
N/A ASTM D149 |
Test Method Flammability Rating |
N/A UL 94 |
Flammability Rating |
N/A Not tested |
Test Method RoHS Compliant |
N/A Chomeric Certification |
RoHS Compliant |
N/A Yes |
Test Method Shelf Life |
N/A Chomerics |
Shelf Life, Months from Date of Shipment |
N/A 12 |