One-part moisture cure
Unit of Measure
Specifications
Type |
N/A Thermally Conductive Adhesives |
Product Form |
N/A One-Part |
Color |
N/A Gray |
Viscosity |
N/A 200000 mPa/s |
Durometer |
N/A 69 A |
Tensile Strength |
N/A 754 psi5.2 MPa53 kgf/cm² |
Elongation |
N/A 120 % |
Specific Gravity |
N/A 2.17 |
Linear CTE |
N/A 203 µ/mC |
Working Time at Room Temperature1 | N/A < 10 min |
Room Temperature Cure Time2 | N/A 144 h |
Unprimed Adhesion Lap Shear |
N/A 230 psi160 N/cm²16 kgf/cm² |
Thermal Conductivity3 | N/A 0.9 W/m·K |
Shelf Life from Date of Manufacture |
N/A 9 months |
Dielectric Strength |
N/A 365 V/mil14.3 kV/mm |
Dielectric Constant at 100 Hz |
N/A 4.44 |
Dielectric Constant at 100 kHz |
N/A 4.38 |
Dielectric Constant at 1 MHz |
N/A 4.9 |
Dissipation Factor at 100 Hz |
N/A 0.00498 |
Dissipation Factor at 100 kHz |
N/A 0.00498 |
Dissipation Factor at 1 MHz |
N/A 0.006 |
Volume Resistivity |
N/A 5.00E+15 O/cm |
- 1 Time to double initial mixed viscosity.
- 2 Cure time for 3 mm thickness at 20 °C (68 °F) and 55 % relative humidity.
- 3 Thermal Conductivity at 25 ºC (77 ºF)