Print Back
Two-part; thermally conductive elastomer
Unit of Measure

Specifications

Type

Thermally Conductive Materials for Pad Manufacturing

Product Form

Two-Part

Color

Gray

Viscosity

5600 mPa/s

Durometer

70 OO

Penetration (1/10 of mm)

35

Tensile Strength

60 psi0.4 MPa4.2 kgf/cm²

Elongation

400 %

Specific Gravity

2.2

Linear CTE

174 µ/mC
Working Time at Room Temperature1 4 h
Room Temperature Cure Time2 7 h
Heat Cure Time at 100 ºC (212 ºF)3 3.5 min
Heat Cure Time at 125 ºC (257 ºF)4 2.5 min
Heat Cure Time at 150 ºC (302 ºF)5 1.9 min
Thermal Conductivity6 0.95 W/m·K

Shelf Life from Date of Manufacture

8 months

Dielectric Strength

455 V/mil17.9 kV/mm

Dielectric Constant at 100 Hz

4.6

Dielectric Constant at 100 kHz

4.6

Dissipation Factor at 100 Hz

0.002

Dissipation Factor at 100 kHz

0.00015

Volume Resistivity

1.90E+14 O/cm

Features

N/A
Soft; good thermal conducitvity; low viscosity

Potential Uses

N/A
Base material for thermally conductive pads

Application Methods

N/A
Manual or automated meter-mix

  • 1 Time to double initial mixed viscosity.
  • 2 Cure time for 3 mm thickness at 20 °C (68 °F) and 55 % relative humidity.
  • 3 Time to 90 percent of final hardness and adhesion or 90 % of curve height for elastic modulus; additional time may be required for the part to warm to near oven temperature.
  • 4 Time to 90 percent of final hardness and adhesion or 90 % of curve height for elastic modulus; additional time may be required for the part to warm to near oven temperature.
  • 5 Time to 90 percent of final hardness and adhesion or 90 % of curve height for elastic modulus; additional time may be required for the part to warm to near oven temperature.
  • 6 Thermal Conductivity at 25 ºC (77 ºF)