| Items |
T609 CHO-THERM® - Comercial Grade Thermally Conductive Electrical Insulator Pads |
T444 CHO-THERM® - Comercial Grade Thermally Conductive Electrical Insulator Pads |
1674 CHO-THERM® - Comercial Grade Thermally Conductive Electrical Insulator Pads |
T441/TH 0.20 CHO-THERM® - Comercial Grade Thermally Conductive Electrical Insulator Pads |
T441/TH 0.33 CHO-THERM® - Comercial Grade Thermally Conductive Electrical Insulator Pads |
|||||
| Test Method Color | N/A Visual | |||||||||
| Color | N/A Light green | N/A Beige | N/A Blue | N/A Pink | N/A Pink | |||||
| Test metod Carrier | N/A Visual | |||||||||
| Reinforcement Carrier | N/A Fiberglass | N/A Kapton ® MT | N/A Fiberglass | N/A Fiberglass | N/A Fiberglass | |||||
| Test Method Thicknesses | N/A ASTM D374 | |||||||||
| Thickness | N/A 0.25 mm0.010 in | N/A 0.08 mm0.003 in | N/A 0.25 mm0.010 in | N/A 0.20 mm0.008 in | N/A 0.33 mm0.013 in | |||||
| Thickness Tolerance | N/A ± 0.025 mm± 0.001 in | N/A ± 0.013 mm± 0.0005 in | N/A ± 0.025 mm± 0.001 in | N/A ± 0.025 mm± 0.001 in | N/A ± 0.025 mm± 0.001 in | |||||
| Test Method Specific Gravity | N/A ASTM D792 | |||||||||
| Specific Gravity | N/A 2.10 | N/A 1.70 | N/A 2.45 | N/A 2.45 | N/A 2.45 | |||||
| Test Method Hardness | N/A ASTM D2240 | |||||||||
| Hardness, Shore A | N/A 70 | N/A 90 | N/A 85 | N/A 80 | N/A 80 | |||||
| Operating Temperature Range | N/A –40 to 200 ºC–40 to 392 ºF | |||||||||
| Test Method Thermal Impedance | N/A ASTM D5470 | |||||||||
| Thermal Impedance | N/A 2.1 ºC-cm²/W0.33 ºC-in²/W | N/A 2.4 ºC-cm²/W0.37 ºC-in²/W | N/A 2.6 ºC-cm²/W0.41 ºC-in²/W | N/A 2.6 ºC-cm²/W0.41 ºC-in²/W | N/A 3.6 ºC-cm²/W0.56 ºC-in²/W | |||||
| Test Method Apparen Thermal Conductivity | N/A ASTM D5470 | |||||||||
| Apparen Thermal Conductivity | N/A 1.5 W/m·K | N/A 0.4 W/m·K | N/A 1.0 W/m·K | N/A 1.1 W/m·K | N/A 1.1 W/m·K | |||||
| Test Method Heat Capacity | N/A ASTM E1269 | |||||||||
| Heat Capacity | N/A 1.0 J/g-ºC | |||||||||
| Test Method Coefficient of Thermal Expansion | N/A ASTM E831 | |||||||||
| Coefficient of Thermal Expansion | N/A 150 ppm/ºC | N/A 400 ppm/ºC | N/A 300 ppm/ºC | N/A 300 ppm/ºC | N/A 300 ppm/ºC | |||||
| Test Method Volume Resistivity Dry | N/A ASTM D257 | |||||||||
| Volume Resistivity Dry | N/A 1014 O/cm | |||||||||
| Test Method Volume Resistivity Wet | N/A ASTM D257 | |||||||||
| Volume Resistivity Wet | N/A Not tested | N/A Not tested | N/A Not tested | N/A 1014 O/cm | N/A 1014 O/cm | |||||
| Test Method Voltage Breakdown Dry | N/A ASTM D149 | |||||||||
| Voltage Breakdown Dry | N/A 4000 Vac | N/A 5000 Vac | N/A 2500 Vac | N/A 8700 Vac | N/A 11400 Vac | |||||
| Test Method Voltage Breakdown Wet | N/A ASTM D149 | |||||||||
| Voltage Breakdown Wet | N/A Not tested | N/A Not tested | N/A Not tested | N/A 8100 Vac | N/A 10500 Vac | |||||
| Test Method Tensile Strength | N/A ASTM D412 | |||||||||
| Tensile Strength | N/A 26.9 MPa3900 psi | N/A 20.7 MPa3000 psi | N/A 10.3 MPa15000 psi | N/A 19.3 MPa2800 psi | N/A 17.3 MPa2500 psi | |||||
| Test Method Tear Strength | N/A ASTM D642 | |||||||||
| Tear Strength | N/A 52.5 kN/m300 lb/in | N/A 26.3 kN/m150 lb/in | N/A 17.5 kN/m100 lb/in | N/A 23.6 kN/m135 lb/in | N/A 19.3 kN/m110 lb/in | |||||
| Test Method Elongation | N/A ASTM D412 | |||||||||
| Elongation | N/A 30 % | N/A | N/A 2 % | N/A 40 % | N/A 40 % | |||||
| Test Method Flammability Rating | N/A UL 94 | |||||||||
| Flammability Rating | N/A V-0 | |||||||||
| Test Method RoHS Compliant | N/A Chomeric Certification | |||||||||
| RoHS Compliant | N/A Yes | |||||||||
| Test Method Outgassing | N/A ASTM E595 | |||||||||
| Outgassing TML | N/A Not tested | N/A Not tested | N/A 0.45 % | N/A Not tested | N/A Not tested | |||||
| Outgassing CVCM | N/A Not tested | N/A Not tested | N/A 0.20 % | N/A Not tested | N/A Not tested | |||||
| Test Method Shelf Life | N/A Chomerics | |||||||||
| Shelf Life, Months from Dry Pad | N/A 24 | N/A 12 | N/A 24 | N/A 24 | N/A 24 | |||||
| Shelf Life, Months from Dry Pad with PSA | N/A 6 | N/A 12 | N/A 12 | N/A 12 | N/A 12 | |||||
|
|
||||||||||